Espressif Systems /ESP32-C2 /EFUSE /RD_RS_ERR

Text Text Text Text Text Text Text Text Text Text Text Text Text Text Text Text Text Text Text Text Text Text Text Text Text Text Text

Interpret as RD_RS_ERR

31 2827 2423 2019 1615 1211 87 43 0 0 0 0 0 0 0 0 00 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0BLK1_ERR_NUM 0 (BLK1_FAIL)BLK1_FAIL 0BLK2_ERR_NUM 0 (BLK2_FAIL)BLK2_FAIL 0BLK3_ERR_NUM 0 (BLK3_FAIL)BLK3_FAIL

Description

Programming error record register 0 of BLOCK1-10.

Fields

BLK1_ERR_NUM

The value of this signal means the number of error bytes in block1.

BLK1_FAIL

0: Means no failure and that the data of block1 is reliable 1: Means that programming user data failed and the number of error bytes is over 6.

BLK2_ERR_NUM

The value of this signal means the number of error bytes in block2.

BLK2_FAIL

0: Means no failure and that the data of block2 is reliable 1: Means that programming user data failed and the number of error bytes is over 6.

BLK3_ERR_NUM

The value of this signal means the number of error bytes in block3.

BLK3_FAIL

0: Means no failure and that the block3 data is reliable 1: Means that programming user data failed and the number of error bytes is over 6.